Product Data Sheets
Countertop Coating
Description: Hard Tops' Countertop Coating is a
two component industrial polyurethane designed to provide superior chemical
abrasion resistance over plastic laminates and cultured marble.
Additionally, it provides cure down to 40 F, with excellent color and gloss
retention. Hard Tops' Countertop Coating is specifically deigned of
application to textured surfaces, such as plastic laminates, where low sheen
film is desired. Our coatings are not an epoxy paint product.
Mixing: Coating to catalyst mixing ratio is
6:1 (i.e. six parts Hard Tops' Countertop Coating to one part Hard Tops'
Catalyst). Mix two parts thoroughly for five minutes prior to use.
Up to four parts of Hard Tops' Reducer may be added for desired spray viscosity.
Surface Preparation: Surface must be clean,
dry, and free of oil, grease, mull scale, and other contaminants. Cleaning
methods include wet-sanding and solvent scrub.
Application: Designed for HVLP application. DO
NOT USE HEATED APPLICATOR
Safety: This product contains solvents
and/or other chemical ingredients. Adequately health and safety
precautions should be observed during all storage, handling, use, and drying
periods. Read material safety data sheet before using this product.
Limitation: This technical data and
suggestions for use in this product data sheet are currently correct to the best
of our knowledge but are subject to change without notice. Because application
and conditions vary and are beyond our control, we are not responsible for
results obtained in using this product, even when used as suggested. The
user should conduct tests to determine the suitability of the product or its use
(including liability for breach of warranty, strict liability in tort,
negligence or otherwise) is limited exclusively to replacement of the product or
refund its price. Under no circumstances are we liable for incidental and
consequential damages.
|
Chemical Resistance Test
Results
10% Hydrochloric Acid.....No Effect
10% Nitric Acid.....No Effect
10% Sulfuric Acid.....No Effect
10% Acetic.....No Effect
50% Sulfuric Acid.....No Effect
85% Phosphoric Acid.....No Effect
50% Potassium Hydroxide.....No Effect
Sydrol.....No Effect
Mustard.....No Effect
Pencil Hardness......HB
Glacial Acetic Hydrochloric Acid......Lifted>1 hr
Coating was cured for one week before exposure to chemicals. Coating was
subjected to four 1-hour exposures to chemicals.
|
|